A flood barrier system is an opening-specific assembly, not just a panel. Interlocking aluminum planks, closed-cell EPDM seals, side channels, any required center post, and compression hardware must form one continuous line across a measured opening.

Professional measurement confirms fit and quote. Visual Fit Check is optional decision support — not a fit guarantee.

Rubicon Flood Panels modular system

Modular aluminum panels for homes, garages, and opening lines

Rapid-deploy 6063-T6 aluminum barriers with EPDM sealing — sized to measured openings, not a one-size catalog kit. Quotes follow on-site width, height, and mounting-surface review.

Rubicon deployable aluminum flood panels installed across a Florida home opening
Measured modular aluminum panels with floor seal — ready for storm deployment.

Product specifications

Alloy and temper
6063-T6
Plank pitch
8 in per plank; height = 8n + 1 inches
System range
3–9 planks · 25–73 in
Plank weight
2.15 lb per linear foot
Plank section depth
1.58 in / 40 mm
Plank wall
0.08 in / 2.03 mm
Post wall
0.15 in / 3.8 mm body; 0.142 in / 3.6 mm back flange
Post profile
3.54 × 2.36 in / 90 × 60 mm
Finish
Electrophoretic coating; powder topcoat optional
Seals
Closed-cell EPDM
Anchoring
Stainless steel sleeve anchors into masonry, bedded in silicone

Specs describe the Rubicon Flood Panels modular panel family. Final layout, panel count, and pricing require measurement.

Repeatable deployment

Homeowners typically stack labeled panels into measured side posts after professional installation, following the opening-specific sequence.

6063-T6 aluminum

The published BarrierX specification identifies 6063-T6 aluminum planks; material identification alone is not a system certification.

EPDM sealing

Closed-cell EPDM sealing faces sit at the floor line and between stacked planks; contact and condition are checked during deployment.

Reusable design

Rinse, inspect, and store between events. One measured system replaces repeat sandbag purchase, transport, and disposal each season.

Decision logic

When Rubicon is a fit — and when to review other paths first

Barriers make sense when water repeatedly crosses an opening line and sandbag labor is unsustainable. Drainage backup, slab seepage, or major grading failures may need review before panels are the first fix.

When Rubicon is a fit

  • ✓Repeat water at garage, door, slider, or lanai thresholds
  • ✓Need a reusable system that homeowners or staff can deploy after professional installation
  • ✓Want measurement-based quote instead of photo-only estimates

When Rubicon may not be first

  • →Water enters through floor drains before reaching the opening
  • →Slab seepage or yard grading bypasses the door line
  • →Opening mounting surfaces cannot support post anchoring without remediation
Recommended path

Review opening types, request professional measurement, and use Visual Fit Check only if you still need help ranking openings

Homeowner researching deployable flood barrier systems and Rubicon Flood Panels fit

Educational

The system architecture

Rubicon Flood Panels use modular 6063-T6 aluminum planks at an 8-inch pitch. Planks stack between measured side channels; closed-cell EPDM creates sealing faces; compression hardware seats the stack; and wide layouts may add a center post.

  • Plank pitch: 8 in; finished height formula: 8n + 1 inches
  • Plank weight: 2.15 lb per linear foot
  • System range: 3–9 planks, 25–73 in

Educational

What each component does

The plank carries across the opening; EPDM seals contact the floor and adjacent planks; side channels locate and retain the stack; center posts divide wider spans where specified; compression hardware applies the installed closing force.

  • No single component creates the barrier line by itself
  • Substrate and floor continuity affect the assembled system
  • Missing supports or incomplete stacks change the intended configuration

Rubicon practice

How the components assemble at an opening

After professional installation, the user clears the seal line, places any specified removable center post, stacks the labeled planks in sequence between channels, and engages the compression hardware. The panels are removed and stored when access is needed.

  • Homeowners or trained staff typically deploy after install
  • Permanent versus removable hardware depends on the layout
  • Storage must preserve labels, seals, and opening assignments

Decision support

Openings this architecture can serve

The same component logic can be configured for garages, entry doors, sliding doors, lanai runs, storefronts, warehouse doors, and other measured openings. Width, height, corners, access, substrate, and water path determine the actual layout.

  • Narrow entries may use a simple two-channel line
  • Wide openings may require center posts
  • Corners and return legs require coordinated layouts

Rubicon practice

Measurement turns components into a system

Rubicon reviews clear width, selected protection height, floor and threshold, jambs, mounting substrate, obstructions, corners, adjacent openings, and likely water bypass. These fields determine plank length, channel placement, support layout, and deployability.

Limitation

When an opening barrier is not first

Opening barriers are a dry-floodproofing component of a building system, not whole-home immunity. Drain backup, slab seepage, wall penetration, grading bypass, or a required depth outside the proposed application calls for broader review.

Example water-path bypass route

  1. Exterior water
  2. Protected opening
  3. Adjacent gap or drain
  4. Slab or track path
  5. Interior floor
Protecting one opening does not stop water that travels around the barrier through an adjacent gap, drain, track, grading path, or slab connection.

Source: FEMA P-2181 Fact Sheet 3.2 — Wall Openings

Common questions

FAQ

What is an aluminum flood barrier?

A reusable modular aluminum plank system that mounts across a measured opening with side posts and seals. Rubicon Flood Panels are aluminum flood barriers sized per opening after professional measurement.

Are aluminum flood barriers reusable?

Yes. Panels deploy before events, store between storms, and redeploy in later seasons when rinsed and inspected.

Can Rubicon quote from photos alone?

No. Photos support a preliminary Visual Fit Check readout. Panel count and pricing require on-site measurement of width, height, and mounting surfaces.

Can homeowners install flood barriers themselves?

Homeowners typically deploy pre-installed systems themselves. Initial measurement, post layout, and system installation are professional steps so the opening and mounting surfaces are confirmed first.

Which opening should I protect first?

Usually the opening water has used before. Garage and low slider lines are common first priorities in Southwest Florida.

Ready for professionally measured aluminum flood barriers?

Rubicon measures each opening on site before quoting panels. Visual Fit Check is optional if you still need help ranking what to protect.